Surge protection for data centres

Internal lightning protection measures offer comprehensive protection of the electrical and electronic systems during lightning strikes and switching operations.
The lightning equipotential bonding is designed for all conductive systems running from the outside into the building.

Low-voltage switchgear assemblyContainer with emergency battery power supplyDiesel generator for emergency power supplyServer room with busbarServer room with separate sub-distribution boardRoof-mounted structuresPV systemSafety camerasSecurity centre / officesLow-voltage switchgear assemblyContainer with emergency battery power supplyDiesel generator for emergency power supplyServer room with busbarServer room with separate sub-distribution boardRoof-mounted structuresPV systemSafety camerasSecurity centre / offices

Product recommendations

DEHNvenCI 255 (FM) - 961205

961205 

DEHNvenCI

Spark-gap-based combined arrester with integrated lightning current arrester backup fuse.

Add  Details
BLITZDUCTORconnect – Modular -

 

BLITZDUCTORconnect

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for the protection of 2 single lines with a common reference potential and unbalanced interfaces. With signal disconnection for maintenance purposes.

Details
DRC SD 2 1 - 910921

910921 

DEHNrecord SD

Multifunctional measuring equipment based on edge computing

Add  Details
DEHNguard M TNS ACI 275 FM - 952440

952440 

DEHNguard modular

Surge arrester with Advanced Circuit Interruption (ACI) for TN-S systems.

Add  Details
BCO ML2 BE - 927224

927224 

BLITZDUCTORconnect

Universal lightning current and surge arrester for protecting measuring and control circuits, bus and telecommunication systems.

Add  Details
DEHNguard M TNS ACI 275 FM - 952440

952440 

DEHNguard modular

Surge arrester with Advanced Circuit Interruption (ACI) for TN-S systems.

Add  Details
DEHNpatch class EA (new) - 929161

929161 

DEHNpatch class EA

The universal surge arrester protects Ethernet applications up to 10Gbit/s and 4PPoE.

Add  Details
DEHNguard M TNS ... FM - 952405

952405 

DEHNguard

For the protecting the power supply in sub-distribution boards.

Add  Details
DEHNflex M - 924396

924396 

DEHNflex M

Surge arrester for single-phase 230 V TT and TN systems for use in all installation systems of terminal equipment; compact dimensions.

Add  Details
DEHNcord 3P TT 275 FM - 900439

900439 

DEHNcord

Compact three-phase arrester for TT and TN-S systems.

Add  Details
DEHNcombo YPV ... - 900070

900070 

DEHNcombo

Combined lightning current and surge arrester for use in photovoltaic power supply systems up to 1500 V d.c.

Add  Details
DPA CLE IP66 - 929221

929221 

DEHNpatch outdoor

Surge arrester for GBit Ethernet applications, power over Ethernet (IEEE 802.3-compliant to PoE++ / 4PPoE) in structured cabling to class E indoors and outdoors. In the IP66 enclosure for protection against the ingress of dust and water.

Add  Details
DEHNrail M 2P ... FM - 953205

953205 

DEHNrail modular

Two-pole surge arrester consisting of a base part and plug-in protection module.

Add  Details
DEHNshield TNS FM - 941405

941405 

DEHNshield TNS FM

Application-optimised and prewired combined lightning current and surge arrester for TN-S systems with a nominal voltage of 230 / 400 V (4+0 configuration)

Add  Details
DEHNpatch class EA (new) - 929161

929161 

DEHNpatch class EA

Universal, space-saving combined arrester of 19 mm in width and RJ45 connection system with status indication for simple maintenance.

Add  Details
DPA M CAT6 - 929100

929100 

DEHNpatch

Universal arrester for Industrial Ethernet, Power over Ethernet (IEEE 802.3 compliant up to PoE++ / 4PPoE) and similar applications

Add  Details
DEHNguard ME DC ... FM - 972147

972147 

DEHNguard ME DC Y 1000 FM

Three-pole, modular, pluggable type 1+2 DEHNguard ME DC Y 1000 FM combined arrester for direct current applications with mechanical function/fault indication.

Add  Details

3 stages for full surge protection

An effective surge protection concept has three protection stages. Stage by stage, the penetrating energy is broken down to a safe degree, so that terminal equipment is secure. The best protective effect is achieved when all protection stages are optimally harmonised. Crucial here is that the arresters of the individual stages are energy-coordinated as per DIN VDE 0100-534.

Stage 1

Type 1 lightning current or
combined arrester
at the point where conductors
enter the building

Stage 2

Type 2 surge arrester
in the sub-distribution board

Stage 3

Type 3 surge arrester
directly on the terminal device or
socket outlet