DEHNcord
- Single-pole, two-pole or three-pole surge protective device with monitoring system and disconnector
- Visual fault indication
- Types with disconnection of the load circuit in the event of a fault and protection of the control phase
- Compact design also for outdoor use
- Can be fitted in junction boxes, flush-mounted systems, cable ducts and flush-type boxes
DEHNcord 3P TT 275 FM
Compact three-phase arrester for TT and TN-S systems.
Part No. 900439
DCOR 3P TT 275 FM
item
DEHNcord 1P 275 D FM
Single-phase, compact arrester for TT and TN-S systems with integrated protective circuit for communication interface.
Part No. 900438
DCOR 1P 275 D FM
item
DEHNcord L 2P
Two-pole surge arrester for all installation systems (1+1 configuration) and luminaires of protection class I; compact design.
Part No. 900430
DCOR L 2P 275
item
DEHNcord L 2P
Two-pole surge arrester for all installation systems (1+1 configuration) and luminaires of protection class I; compact design.
Part No. 900432
DCOR L 2P 320
item
DEHNcord L 1P
Single-pole surge arrester for luminaires of protection class II; compact design.
Part No. 900431
DCOR L 1P 275
item
DEHNcord L 1P
Single-pole surge arrester for luminaires of protection class II; compact design.
Part No. 900433
DCOR L 1P 320
item
DEHNcord L 2P SN1864
Surge arrester for luminaires of protection class II; compact design. With disconnection in the event of a fault.
Part No. 999906
DCOR L 2P SN1864
item
GTIN: 4013364310926, customs tariff number: 85363030, gross weight: 0.071 KG, packaging unit: 1 ST
Surge arrester DEHNcord L 2P SN1864
Multi-pole surge arrester Type 2 according to EN 61643-11
for use in cable junction boxes.
With protection of the control phase
Disconnection of the light in case of fault and
integrated visual fault indication
for supply voltage
Max. continuous operating voltage: 275 V ac
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Total discharge current: 20 kA
Max. mains-side overcurrent
protection: 16 A gG
Max. load current AC: 10 A
Energy coordination acc. to DIN EN 62305-4
with arresters of the Red/Line family
Brand: DEHN
Type: DCOR L 2P SN1864
Part No.: 999906
or equivalent.
Multi-pole surge arrester Type 2 according to EN 61643-11
for use in cable junction boxes.
With protection of the control phase
Disconnection of the light in case of fault and
integrated visual fault indication
for supply voltage
Max. continuous operating voltage: 275 V ac
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Total discharge current: 20 kA
Max. mains-side overcurrent
protection: 16 A gG
Max. load current AC: 10 A
Energy coordination acc. to DIN EN 62305-4
with arresters of the Red/Line family
Brand: DEHN
Type: DCOR L 2P SN1864
Part No.: 999906
or equivalent.
DEHNcord L 2P SN1860
Surge arrester for all installation systems; compact design. With disconnection of the load circuit in the event of a fault.
Part No. 999937
DCOR L 2P SN1860
item
GTIN: 4013364303195, customs tariff number: 85363030, gross weight: 0.086 KG, packaging unit: 1 ST
DEHNcord L 2P SN1860 surge arrester
Multipole type 2 surge arrester according to EN 61643-11
with cables for installation in junction boxes.
LED can be disconnected in case of a fault
Integrated visual fault indication for the supply voltage
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Summary discharge current: 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 2P SN1860
Part No.: 999937
or equivalent.
Multipole type 2 surge arrester according to EN 61643-11
with cables for installation in junction boxes.
LED can be disconnected in case of a fault
Integrated visual fault indication for the supply voltage
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Summary discharge current: 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 2P SN1860
Part No.: 999937
or equivalent.
DEHNcord L 2P 275 SO LTG
Surge arrester for all installation systems; compact design. With disconnection of the load circuit in the event of a fault.
Part No. 900446
DCOR L 2P 275 SO LTG
item
GTIN: 4013364292970, customs tariff number: 85363030, gross weight: 0.063 KG, packaging unit: 1 ST
DEHNcord L 2P 275 SO LTG surge arrester
Multipole type 2 surge arrester according to EN 61643-11
with cables for installation in junction boxes.
LED can be disconnected in case of a fault
Integrated visual fault indication for the supply voltage
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Summary discharge current: 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 2P 275 SO LTG
Part No.: 900446
or equivalent.
Multipole type 2 surge arrester according to EN 61643-11
with cables for installation in junction boxes.
LED can be disconnected in case of a fault
Integrated visual fault indication for the supply voltage
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Summary discharge current: 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 2P 275 SO LTG
Part No.: 900446
or equivalent.
DEHNcord L 3P 275 SO LTG
Three-pole arrester for all installation systems; compact design. With disconnection of the load circuit in the event of a fault and protection of the control phase
Part No. 900445
DCOR L 3P 275 SO LTG
GTIN: 4013364280380, customs tariff number: 85363030, gross weight: 0.072 KG, packaging unit: 1 ST
DEHNcord L 3P 275 SO LTG surge arrester
Multipole type 2 surge arrester according to EN 61643-11
for installation in junction boxes.
Protection of the control phase
LED can be disconnected in case of a fault
Integrated separate visual fault indication for the supply voltage and control phase
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Total discharge current (8/20): 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 3P 275 SO LTG
Part No.: 900445
or equivalent.
Multipole type 2 surge arrester according to EN 61643-11
for installation in junction boxes.
Protection of the control phase
LED can be disconnected in case of a fault
Integrated separate visual fault indication for the supply voltage and control phase
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Total discharge current (8/20): 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 3P 275 SO LTG
Part No.: 900445
or equivalent.
SK EK480 G2S-2d LM DCOR
Part No. 900443
SK EK480 G2S-2d LM DCOR
DEHNcord L 2P 275 SO LT
Two-pole surge arrester for TCN systems; compact design. With disconnection of the load circuit in the event of a fault and protection of the control phase.
Part No. 900435
DCOR L 2P 275 SO LT
item
DEHNcord L 3P 275 SO IP
Three-pole surge arrester for all installation systems; compact design. IP 65 degree of protection. With disconnection of the load circuit in the event of a fault and protection of the control phase.
Part No. 900447
DCOR L 3P 275 SO IP
item
GTIN: 4013364282216, customs tariff number: 85363030, gross weight: 0.147 KG, packaging unit: 1 ST
DEHNcord L 2P 275 SO IP surge arrester
Multipole type 2 surge arrester according to EN 61643-11
with cables for outdoor installation
(IP65 degree of protection) e.g. on junction boxes.
With protection of the control phase
LED can be disconnected in case of a fault
Integrated visual fault indication for the
supply voltage and control phase
With fixing lug
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Summary discharge current: 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 3P 275 SO IP
Part No.: 900447
or equivalent.
Multipole type 2 surge arrester according to EN 61643-11
with cables for outdoor installation
(IP65 degree of protection) e.g. on junction boxes.
With protection of the control phase
LED can be disconnected in case of a fault
Integrated visual fault indication for the
supply voltage and control phase
With fixing lug
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Summary discharge current: 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 3P 275 SO IP
Part No.: 900447
or equivalent.
DEHNcord L 2P 275 SO IP
Two-pole arrester for all installation systems; compact design. IP 65 degree of protection. With disconnection of the load circuit in the event of a fault.
Part No. 900448
DCOR L 2P 275 SO IP
item
GTIN: 4013364293007, customs tariff number: 85363030, gross weight: 0.14 KG, packaging unit: 1 ST
DEHNcord L 2P 275 SO IP surge arrester
Multipole type 2 surge arrester according to EN 61643-11
with cables for outdoor installation
(IP65 degree of protection) e.g. on junction boxes.
LED can be disconnected in case of a fault
Integrated visual fault indication for the supply voltage
With fixing lug
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Summary discharge current: 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 2P 275 SO IP
Part No.: 900448
or equivalent.
Multipole type 2 surge arrester according to EN 61643-11
with cables for outdoor installation
(IP65 degree of protection) e.g. on junction boxes.
LED can be disconnected in case of a fault
Integrated visual fault indication for the supply voltage
With fixing lug
Max. continuous operating voltage: 275 V a.c.
Voltage protection level: <= 1.5 kV
Nominal discharge current (8/20): 5 kA
Summary discharge current: 20 kA
Follow current extinguishing capability [N-PE]: 100 A rms
Max. mains-side overcurrent protection: 16 A gG
Max. load current (a.c.): 10 A
Energy coordination with arresters
of the Red/Line series according to EN 62305-4
Brand: DEHN
Type: DCOR L 2P 275 SO IP
Part No.: 900448
or equivalent.
DEHNcord R 3P
Surge arrester for electric Venetian blinds; compact design.
Part No. 900449
DCOR R 3P 275
item