Three-pole, same Cable Cross-Section with Ball Head Caps
Art.-Nr. VGJD2QX
EKV3+1 16 G VGJD2QX
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 16 mm² |
| Max. short-circuit current Ik 0.5 s | 4.5 kA |
| Max. short-circuit current Ik 1 s | 3.2 kA |
Three-pole, same Cable Cross-Section with Ball Head Caps
Art.-Nr. VRDSN66
EKV3+1 25 G VRDSN66
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 25 mm² |
| Max. short-circuit current Ik 0.5 s | 7.0 kA |
| Max. short-circuit current Ik 1 s | 4.9 kA |
Three-pole, same Cable Cross-Section with Ball Head Caps
Art.-Nr. V3WJMYY
EKV3+1 35 G V3WJMYY
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 35 mm² |
| Max. short-circuit current Ik 0.5 s | 10.0 kA |
| Max. short-circuit current Ik 1 s | 6.9 kA |
Three-pole, same Cable Cross-Section with Ball Head Caps
Art.-Nr. VU8P6LE
EKV3+1 50 G VU8P6LE
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 50 mm² |
| Max. short-circuit current Ik 0.5 s | 14.0 kA |
| Max. short-circuit current Ik 1 s | 9.9 kA |
Three-pole, same Cable Cross-Section with Ball Head Caps
Art.-Nr. VCEY1U6
EKV3+1 70 G VCEY1U6
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 70 mm² |
| Max. short-circuit current Ik 0.5 s | 19.5 kA |
| Max. short-circuit current Ik 1 s | 13.8 kA |
Three-pole, same Cable Cross-Section with Ball Head Caps
Art.-Nr. VA3926U
EKV3+1 95 G VA3926U
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 95 mm² |
| Max. short-circuit current Ik 0.5 s | 26.5 kA |
| Max. short-circuit current Ik 1 s | 18.7 kA |
Three-pole, same Cable Cross-Section with Ball Head Caps
Art.-Nr. VAB3PJV
EKV3+1 120 G VAB3PJV
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 120 mm² |
| Max. short-circuit current Ik 0.5 s | 33.5 kA |
| Max. short-circuit current Ik 1 s | 23.7 kA |
Three-pole, same Cable Cross-Section with Ball Head Caps
Art.-Nr. V1KPXFR
EKV3+1 150 G V1KPXFR
| Phase cable end | KKH 25 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 25 mm |
| Cable cross-section Cu | 150 mm² |
| Max. short-circuit current Ik 0.5 s | 42.0 kA |
| Max. short-circuit current Ik 1 s | 29.6 kA |
Three-pole, reduced Cable Cross-Section with Ball Head Caps
Art.-Nr. VD28FAD
EKV3+1 50 R VD28FAD
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 50/25 mm² |
| Max. short-circuit current Ik 0.5 s | 14.0 kA |
| Max. short-circuit current Ik 1 s | 9.9 kA |
Three-pole, reduced Cable Cross-Section with Ball Head Caps
Art.-Nr. VQYP8B2
EKV3+1 70 R VQYP8B2
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 70/35 mm² |
| Max. short-circuit current Ik 0.5 s | 19.5 kA |
| Max. short-circuit current Ik 1 s | 13.8 kA |
Three-pole, reduced Cable Cross-Section with Ball Head Caps
Art.-Nr. V5SVXPH
EKV3+1 95 R V5SVXPH
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 95/35 mm² |
| Max. short-circuit current Ik 0.5 s | 26.5 kA |
| Max. short-circuit current Ik 1 s | 18.7 kA |
Three-pole, reduced Cable Cross-Section with Ball Head Caps
Art.-Nr. VTSY9XH
EKV3+1 120 R VTSY9XH
| Phase cable end | KKH 20 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 20 mm |
| Cable cross-section Cu | 120/50 mm² |
| Max. short-circuit current Ik 0.5 s | 33.5 kA |
| Max. short-circuit current Ik 1 s | 23.7 kA |
Three-pole, reduced Cable Cross-Section with Ball Head Caps
Art.-Nr. VHBWUNH
EKV3+1 150 R VHBWUNH
| Phase cable end | KKH 25 SK |
| Earth cable end | EAS EK FM 12 |
| For fixed ball point Ø | 25 mm |
| Cable cross-section Cu | 150/50 mm² |
| Max. short-circuit current Ik 0.5 s | 42.0 kA |
| Max. short-circuit current Ik 1 s | 29.6 kA |
Three-pole, same Cable Cross-Section with Universal Clamp
Art.-Nr. V8MCNWM
EKV3+1 16 G V8MCNWM
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 16 mm² |
| Max. short-circuit current Ik 0.5 s | 4.5 kA |
| Max. short-circuit current Ik 1 s | 3.2 kA |
Three-pole, same Cable Cross-Section with Universal Clamp
Art.-Nr. V8VF7CP
EKV3+1 25 G V8VF7CP
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 25 mm² |
| Max. short-circuit current Ik 0.5 s | 7.0 kA |
| Max. short-circuit current Ik 1 s | 4.9 kA |
Three-pole, same Cable Cross-Section with Universal Clamp
Art.-Nr. V5VN56Z
EKV3+1 35 G V5VN56Z
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 35 mm² |
| Max. short-circuit current Ik 0.5 s | 10.0 kA |
| Max. short-circuit current Ik 1 s | 6.9 kA |
Three-pole, same Cable Cross-Section with Universal Clamp
Art.-Nr. VPH98CT
EKV3+1 50 G VPH98CT
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 50 mm² |
| Max. short-circuit current Ik 0.5 s | 14.0 kA |
| Max. short-circuit current Ik 1 s | 9.9 kA |
Three-pole, same Cable Cross-Section with Universal Clamp
Art.-Nr. VMLM2BZ
EKV3+1 70 G VMLM2BZ
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 70 mm² |
| Max. short-circuit current Ik 0.5 s | 19.5 kA |
| Max. short-circuit current Ik 1 s | 13.8 kA |
Three-pole, same Cable Cross-Section with Universal Clamp
Art.-Nr. VE9HQHJ
EKV3+1 95 G VE9HQHJ
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 95 mm² |
| Max. short-circuit current Ik 0.5 s | 26.5 kA |
| Max. short-circuit current Ik 1 s | 18.7 kA |
Three-pole, same Cable Cross-Section with Universal Clamp
Art.-Nr. VKZLVU3
EKV3+1 120 G VKZLVU3
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 120 mm² |
| Max. short-circuit current Ik 0.5 s | 33.5 kA |
| Max. short-circuit current Ik 1 s | 23.7 kA |
Three-pole, reduced Cable Cross-Section with Universal Clamp
Art.-Nr. VMBDCM1
EKV3+1 50 R VMBDCM1
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 50/25 mm² |
| Max. short-circuit current Ik 0.5 s | 14.0 kA |
| Max. short-circuit current Ik 1 s | 9.9 kA |
Three-pole, reduced Cable Cross-Section with Universal Clamp
Art.-Nr. V4RJ7A2
EKV3+1 70 R V4RJ7A2
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 70/35 mm² |
| Max. short-circuit current Ik 0.5 s | 19.5 kA |
| Max. short-circuit current Ik 1 s | 13.8 kA |
Three-pole, reduced Cable Cross-Section with Universal Clamp
Art.-Nr. VRAB9WB
EKV3+1 95 R VRAB9WB
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 95/35 mm² |
| Max. short-circuit current Ik 0.5 s | 26.5 kA |
| Max. short-circuit current Ik 1 s | 18.7 kA |
Three-pole, reduced Cable Cross-Section with Universal Clamp
Art.-Nr. VACNLP8
EKV3+1 120 R VACNLP8
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 25 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 120/50 mm² |
| Max. short-circuit current Ik 0.5 s | 33.5 kA |
| Max. short-circuit current Ik 1 s | 23.7 kA |
Single-pole with Phase Screw Clamp
Art.-Nr. VE5E8FZ
EKV1+1 16 VE5E8FZ
| Phase cable end | PSK 4 30 SQL |
| Earth cable end | EFK FL40 SKN |
| Clamping range Ø | 4 ... 30 mm |
| Cable cross-section Cu | 16 mm² |
| Max. short-circuit current Ik 0.5 s | 4.5 kA |
| Max. short-circuit current Ik 1 s | 3.2 kA |
Single-pole with Phase Screw Clamp
Art.-Nr. VF33XR2
EKV1+1 25 VF33XR2
| Phase cable end | PSK 4 30 SQL |
| Earth cable end | EFK FL40 SKN |
| Clamping range Ø | 4 ... 30 mm |
| Cable cross-section Cu | 25 mm² |
| Max. short-circuit current Ik 0.5 s | 7.0 kA |
| Max. short-circuit current Ik 1 s | 4.9 kA |
Single-pole with Phase Screw Clamp
Art.-Nr. V43FCV8
EKV1+1 35 V43FCV8
| Phase cable end | PSK 4 30 SQL |
| Earth cable end | EFK FL40 SKN |
| Clamping range Ø | 4 ... 30 mm |
| Cable cross-section Cu | 35 mm² |
| Max. short-circuit current Ik 0.5 s | 10.0 kA |
| Max. short-circuit current Ik 1 s | 6.9 kA |
Single-pole with Phase Screw Clamp
Art.-Nr. V2KWXUL
EKV1+1 50 V2KWXUL
| Phase cable end | PSK 4 30 SQL |
| Earth cable end | EFK FL40 SKN |
| Clamping range Ø | 4 ... 30 mm |
| Cable cross-section Cu | 50 mm² |
| Max. short-circuit current Ik 0.5 s | 14.0 kA |
| Max. short-circuit current Ik 1 s | 9.9 kA |
Single-pole with Phase Screw Clamp
Art.-Nr. VRP32FL
EKV1+1 70 VRP32FL
| Phase cable end | PSK 4 30 SQL |
| Earth cable end | EFK FL40 SKN |
| Clamping range Ø | 4 ... 30 mm |
| Cable cross-section Cu | 70 mm² |
| Max. short-circuit current Ik 0.5 s | 19.5 kA |
| Max. short-circuit current Ik 1 s | 13.8 kA |
Single-pole with Phase Screw Clamp
Art.-Nr. V2WPYVF
EKV1+1 95 V2WPYVF
| Phase cable end | PSK 10 65 SQL |
| Earth cable end | UEK 30 HG |
| Clamping range Ø | 10 ... 65 mm |
| Cable cross-section Cu | 95 mm² |
| Max. short-circuit current Ik 0.5 s | 26.5 kA |
| Max. short-circuit current Ik 1 s | 18.7 kA |
Single-pole with Phase Screw Clamp
Art.-Nr. VG4GXHQ
EKV1+1 120 VG4GXHQ
| Phase cable end | PSK 10 65 SQL |
| Earth cable end | UEK 30 HG |
| Clamping range Ø | 10 ... 65 mm |
| Cable cross-section Cu | 120 mm² |
| Max. short-circuit current Ik 0.5 s | 33.5 kA |
| Max. short-circuit current Ik 1 s | 23.7 kA |
Single-pole with Universal Clamp
Art.-Nr. VMZDL8N
EKV1+1 16 VMZDL8N
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 30 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 16 mm² |
| Max. short-circuit current Ik 0.5 s | 4.5 kA |
| Max. short-circuit current Ik 1 s | 3.2 kA |
Single-pole with Universal Clamp
Art.-Nr. VB1DETL
EKV1+1 25 VB1DETL
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 30 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 25 mm² |
| Max. short-circuit current Ik 0.5 s | 7.0 kA |
| Max. short-circuit current Ik 1 s | 4.9 kA |
Single-pole with Universal Clamp
Art.-Nr. V8PPJEF
EKV1+1 35 V8PPJEF
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 30 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 35 mm² |
| Max. short-circuit current Ik 0.5 s | 10.0 kA |
| Max. short-circuit current Ik 1 s | 6.9 kA |
Single-pole with Universal Clamp
Art.-Nr. VQY44GL
EKV1+1 50 VQY44GL
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 30 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 50 mm² |
| Max. short-circuit current Ik 0.5 s | 14.0 kA |
| Max. short-circuit current Ik 1 s | 9.9 kA |
Single-pole with Universal Clamp
Art.-Nr. VFZ17TJ
EKV1+1 70 VFZ17TJ
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 30 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 70 mm² |
| Max. short-circuit current Ik 0.5 s | 19.5 kA |
| Max. short-circuit current Ik 1 s | 13.8 kA |
Single-pole with Universal Clamp
Art.-Nr. VWBDMPS
EKV1+1 95 VWBDMPS
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 30 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 95 mm² |
| Max. short-circuit current Ik 0.5 s | 26.5 kA |
| Max. short-circuit current Ik 1 s | 18.7 kA |
Single-pole with Universal Clamp
Art.-Nr. V3CM9FR
EKV1+1 120 V3CM9FR
| Phase cable end | UK 25 SQ |
| Earth cable end | UEK 30 HG |
| For fixed ball point Ø | 20 / 25 mm |
| For T pins with a collar width of | 15 mm |
| Rd / Fl clamping range | 20 mm |
| Cable cross-section Cu | 120 mm² |
| Max. short-circuit current Ik 0.5 s | 33.5 kA |
| Max. short-circuit current Ik 1 s | 23.7 kA |