DEHNbox

Universal Lightning Current / Surge Arrester

DEHNbox used for a telecommunication connection (example: Uk0interface)
    Combined lightning current and surge arrester
  • Capable of carrying lightning currents up to 10 kA (10/350 µs)
  • Low voltage protection level, capable of protecting terminal equipment
  • For installation in conformity with the lightning protection zone concept at the boundaries from 0A – 2 and higher
  • Easy to use
  • Suitable for wall mounting
  • Fast and easy installation due to spring-loaded terminals
  • Easy retrofitting of surge protection
  • Safe installation and operation (DBX TC B 180)
  • Status indication for easy maintenance
  • RJ45 connection possibility for plug & play
  • Universal use up to 1 Gbit

Description

DEHNbox
The compact arresters of the DEHNbox product family are combined lightning current and surge arresters designed for protecting information, measuring and control and automation equipment and systems. With its surface-mounted plastic enclosure with integrated fixing lugs, DEHNbox is ideally suited for wall mounting and can be easily retrofitted into existing equipment and systems. The IP 65 degree of protection allows DEHNbox TC 180 and DBX U4 KT BD S 0-180 to be used in harsh environments such as in moist atmospheres. The cable entries are designed as installation-friendly self-sealing rubber grommets. These grommets allow easy and fast installation and prevent the ingress of moisture and dust. Both the cores and an installed line shield can be contacted via spring-loaded terminals without the need for screws. DEHNbox is available in three versions:

DEHNbox TC B 180
DEHNbox TC B 180 has been specifically developed to meet the latest requirements of telecommunication applications such as VDSL2 vectoring and G.fast (up to 1 Gbit). The main focus of this surge arrester is, in addition to optimum protection of the terminal equipment, on low-attenuation signal transmission and simple handling. Due to the special snap-in cover of the IP 20 enclosure, several arresters can be locked together and screwed to the wall. The telephone line is mounted at the input without tools via push-in terminals. On the output side, the connecting line can be connected to push-in terminals or an RJ45 socket, depending on the application (mounting near the network termination or directly on the router). It is also possible to earth the cable shield directly or indirectly. With a maximum continuous operating voltage of 180 V d.c. and a maximum operating current of 1 A, the DBX TC B 180 can also be universally used in non-telecommunications applications to protect measuring and control interfaces and other applications.

DEHNbox TC 180
The arrester is optimised for use at telecommunication connections and devices such as analogue telephones as well as ISDN and VDSL2 connections. With a cut-off frequency of 250 MHz, the arrester is also capable of transmitting high-frequency signal parts and can thus be used at high-performance signal interfaces. As an alternative, DEHNbox TC 180 can also be installed at measuring and control interfaces up to a voltage of 180 V and a maximum current of 750 mA.
DEHNbox TC 180 enables the fast connection of one pair without tools and makes it possible to use cable ties to fix the connection cable to the printed circuit board (strain relief). The connection space in the box and the position of the terminals ensure optimal conductor routing and easy conductor connection.

DEHNbox with actiVsense technology
This arrester type does not have a specific nominal voltage and can thus be used for voltages ranging from 0 to 180 V with a superimposed signal voltage (± 5 V/50 MHz). The nominal current is limited to 100 mA which is sufficient for information technology systems. This innovative actiVsense technology allows the arrester to detect the signal voltage applied and to automatically adapt the voltage protection level to this voltage. This makes the arrester ideal for applications where changing or slowly fluctuating signal levels (≤ 400 Hz) are to be expected. In case of interference, DEHNbox arresters have an adapted voltage protection level for every signal voltage, thus providing maximum protection for the devices and system circuits connected to them. The four-pole version of DEHNbox provides protection for two different balanced interfaces, e.g. a bus interface with a system voltage of 5 V and an analogue measured value signal with a system voltage of 24 V. The arrester is ideally suited for domestic and industrial use in information technology transmission systems such as telecommunication, bus and measuring and control systems.

Detail 1

Push-in terminals for fast connection without tools (DBX TC B 180)

Detail 2

RJ45 socket at the output for direct connection to the router (DBX TC B 180).

Detail 3

Visual status display (DBX TC B 180).

Detail 4

Side-by-side mounting of several devices thanks to slide-in dovetail connections on the enclosures (DBX TC B 180).

Models

+
DBX TC B 180

DBX TC 180

DBX U4 KT BD S 0-180

+ DBX TC B 180

Basic circuit diagram DBX TC B 180Dimension drawing DBX TC B 180

Space-saving, compact surge arrester in a surface-mounted plastic enclosure with push-in connection technology and status indication for protecting one pair of unearthed balanced interfaces, particularly telecommunication interfaces up to VVDSL and G.fast (up to 1 Gbit/s). Direct / indirect shield earthing possible. Connection of a pair or a patch cable with RJ45 plug at the output.

Tests by Deutsche Telekom Technik GmbH confirm compatibility with vectoring VDSL (VVDSL), super vectoring VDSL (SVVDSL) and G.Fast.


Specifications

Type
Part No.
SPD class
Impulse category
Nominal voltage (UN)
Max. continuous operating voltage (d.c.) (UC)
Max. continuous operating voltage (a.c.) (UC)
Nominal current (IL)
D1 Total lightning impulse current (10/350 µs) ( Iimp)
D1 Lightning impulse current (10/350 µs) per line ( Iimp)
C2 Total nominal discharge current (8/20 µs) ( In)
C2 Nominal discharge current (8/20 µs) per line ( In)
Voltage protection level line-line for In C2 (Up)
Voltage protection level line-PG for In C2 (Up)
Voltage protection level line-line at 1 kV/µs C3 (Up)
Voltage protection level line-PG at 1 kV/µs C3 (Up)
Series resistance per line
Cut-off frequency (fG)
Capacitance line-line (C)
Capacitance line-PG (C)
Operating temperature range (TU)
Operating state / fault indication
Degree of protection
Cross-sectional area (solid)
Cross-sectional area (flexible)
Cross-sectional area of the earth terminal
Enclosure material
Connection (input)
Connection (output)
Colour
Test standards
Approvals
Weight
GTIN
PU
Part No.
  • DBX TC B 180
  • 922 220
  • L
  • D1, C1, C2, C3
  • 180 V
  • 180 V
  • 127 V
  • 1 A
  • 7.5 kA
  • 2.5 kA
  • 20 kA
  • 10 kA
  • ≤ 700 V
  • ≤ 550 V
  • ≤ 620 V
  • ≤ 550 V
  • 0 ohms
  • 425 MHz
  • ≤ 10 pF
  • ≤ 20 pF
  • -25 °C ... +80 °C
  • green / red
  • IP 20
  • 0.2-1.5 mm2
  • 0.25-1.5 mm2
  • 0.08-4 mm2
  • polyamide PA 6.6
  • push-in
  • push-in / RJ45
  • yellow
  • IEC 61643-21 / EN 61643-21
  • EAC
  • 64 g
  • 4013364433953
  • 1 pc(s)
  • 922 220
  • Specifications (PDF)
  • More

DBX TC 180

Basic circuit diagram DBX TC 180Dimension drawing DBX TC 180

Compact combined arrester in a surface-mounted plastic enclosure for protecting information technology interfaces, particularly telecommunication connections and devices such as analogue telephones, ISDN and xDSL (VDSL2-tested). Fast connection of one pair without tools and possibility of strain relief for the connecting cable by means of a cable tie (not included in delivery). Cut-off frequency up to 250 MHz ensures maximum transmission performance in case of high-frequency signal parts.


Specifications

Type
Part No.
SPD class
Nominal voltage (UN)
Max. continuous operating voltage (d.c.) (UC)
Max. continuous operating voltage (a.c.) (UC)
Nominal current at 45°C (IL)
D1 Total lightning impulse current (10/350 µs) ( Iimp)
D1 Lightning impulse current (10/350 µs) per line ( Iimp)
C2 Total nominal discharge current (8/20 µs) ( In)
C2 Nominal discharge current (8/20 µs) per line ( In)
Voltage protection level line-line at 1 kV/µs C3 (Up)
Voltage protection level line-PG at 1 kV/µs C3 (Up)
Voltage protection level line-line for Iimp D1 (Up)
Voltage protection level line-PG for Iimp D1 (UP)
Series resistance per line
Cut-off frequency line-line (100 ohms) (fG)
Capacitance line-line (C)
Capacitance line-PG (C)
Operating temperature range (TU)
Degree of protection
Cross-sectional area of the signal lines, solid
Cross-sectional area of the signal lines, flexible
Cross-sectional area of the earth terminal
Dimensions (L x W x H)
Enclosure material
Colour
Test standards
Approvals
Weight
GTIN
PU
Part No.
  • DBX TC 180
  • 922 210
  • L
  • 180 V
  • 180 V
  • 127 V
  • 0.75 A
  • 7.5 kA
  • 2.5 kA
  • 15 kA
  • 7.5 kA
  • ≤ 250 V
  • ≤ 550 V
  • ≤ 300 V
  • ≤ 550 V
  • 1.8 ohms
  • 250 MHz
  • ≤ 20 pF
  • ≤ 10 pF
  • -25 °C ... +40 °C
  • IP 65
  • 0.2-1.5 mm2
  • 0.25-1.5 mm2
  • 0.25-2.5 mm2
  • 93 x 93 x 55 mm
  • polycarbonate
  • grey
  • IEC 61643-21 / EN 61643-21
  • EAC
  • 138 g
  • 4013364158214
  • 1 pc(s)
  • 922 210
  • Specifications (PDF)
  • More

DBX U4 KT BD S 0-180

Basic circuit diagram DBX U4 KT DB S 0-180Dimension drawing DBX U4 KT DB S 0-180

Compact combined lightning current and surge arrester in a surface-mounted plastic enclosure with actiVsense technology for protecting two pairs with the same or a different signal voltage of galvanically isolated balanced interfaces. Direct or indirect shield earthing.


Specifications

Type
Part No.
SPD class
Nominal voltage (UN)
Frequency of the nominal voltage (fUN)
Max. continuous operating voltage (d.c.) (UC)
Permissible superimposed signal voltage (Usignal)
Cut-off frequency line-line (Usignal, balanced 100 ohms) (fG)
Nominal current IL (equals max. short-circuit current)
D1 Total lightning impulse current (10/350 µs) ( Iimp)
D1 Lightning impulse current (10/350 µs) per line ( Iimp)
C2 Total nominal discharge current (8/20 µs) ( In)
C2 Nominal discharge current (8/20 µs) per line ( In)
Voltage protection level line-line for In C2 (Up)
Voltage protection level line-line at 1 kV/µs C3 (Up)
Voltage protection level line-line for Iimp D1 (Up)
Voltage protection level line-PG for D1/C2/C3
Series resistance per line
Capacitance line-line (C)
Capacitance line-PG (C)
Operating temperature range (TU)
Degree of protection
Cross-sectional area of the signal lines
Cross-sectional area of the earth terminal
Dimensions (L x W x H)
Enclosure material
Colour
Test standards
Approvals
Weight
GTIN
PU
Part No.
  • DBX U4 KT BD S 0-180
  • 922 400
  • M
  • 0-180 V
  • 0-400 Hz
  • 180 V
  • ≤ +/- 5 V
  • 50 MHz
  • 100 mA
  • 10 kA
  • 2.5 kA
  • 20 kA
  • 10 kA
  • see diagram, line C2
  • see diagram, line C3
  • ≤ UN + 50 V
  • ≤ 550 V
  • ≤ 9 ohms; typically 7.9 ohms
  • ≤ 80 pF
  • ≤ 70 pF
  • -25 °C ... +40 °C
  • IP 65
  • 0.08-1.5 mm2
  • 2.5-4 mm2
  • 93 x 93 x 55 mm
  • polycarbonate
  • grey
  • IEC 61643-21 / EN 61643-21
  • EAC
  • 220 g
  • 4013364137349
  • 1 pc(s)
  • 922 400
  • Specifications (PDF)
  • More
    • Further Pictures
      Basic circuit diagram DBX U4 KT DB S 0-180
      open PDF
      Voltage protection level diagram DBX
      open PDF
      Further Information
      Product Specifications (Text)

      Back

      Compact DEHNbox DBX U4 KT BD S 0-180 combined arrester
      Universal type 1/P1 lightning current and surge  
      arrester with actiVsense technology 
      for automatic detection of the operating voltage 
      and optimal adaptation of the voltage protection 
      level; tested to EN 61643-21 and energy-coordinated 
      according to IEC 61643-22 for protecting two pair
      for galvanically isolated balanced interfaces,
      optional direct or indirect shield earthing
      Operating voltage: UN: 0-180 V 
      Permissible superimposed signal voltage: ≤ +/- 5 V
      Nominal current IL (equals max. short-circuit current): 100 mA
      D1 Total lightning impulse current (10/350 µs): 10 kA
      C2 Total nominal discharge current (8/20 µs): 20 kA

      delivery and installation.

      Brand: DEHN
      Type: DBX U4 KT BD S 0-180
      Part No.: 922 400

      or equivalent.
      Installation Instructions
      Certificates
      CE_DBX_U4_KT_BD_S_0_180
      CAD-Data for registered Users
      922210.stp
      922210.igs
      922210.jt
      922210.dwg
      922200_400m_D.dxf