Connection elements for HVI light plus Conductor

Mounting-optimised connection elements for routing inside/outside the tube and connection to the earthing system, ring conductor or other parts of the external lightning protection system.

Connection element for HVI light plus Conductor

A connection element for sealing the HVI light plus Conductor, for implementing the sealing end of the conductor on the supporting tube (head piece) or for connecting to other parts of the external lightning protection system or earth-termination system (including a heat-shrinkable sleeve).
This connection element can be used for installation outside the tube for HVI light plus supporting tubes.
Art.-Nr. 819640
AE BO10 KF HVI 60 V2A
item

Connection kit for HVI light plus Conductor for installation inside the tube

Two connection elements for sealing the HVI light plus Conductor at both ends. A connection element for implementing the sealing end of the conductor in the supporting tube (head piece) and a connection element for connecting to other parts of the external lightning protection system or earth-termination system (including two heat-shrinkable sleeves).
These connection elements can be used with HVI light plus supporting tubes.
Art.-Nr. 819645
HVI LI PL ASS RIV KF V2A
item

Testable, insulated connection elements for HVI light plus Conductor

An insulating connection element for sealing the HVI light plus Conductor on the earth side.
By using insulating connection elements, a dielectric withstand test can be carried out on the HVI light plus Conductor. This insulating connection element can be used for connecting the HVI light plus to earth.
Art.-Nr. 819646
AE ISO BO10 KF HVI 60 V2A
New
item

Testable, insulated connection elements for HVI light plus Conductor

An insulating connection element for sealing the HVI light plus Conductor when installed inside the tube.
By using insulating connection elements, a dielectric withstand test can be carried out on the HVI light plus Conductor. This insulating connection element can be used for installation inside the supporting tube, Ø40 mm and Ø50 mm.
Art.-Nr. 819647
AE ISO RIV KF HVI 60 V2A
New
item

Testable, insulated connection elements for HVI light plus Conductor

A connection element for sealing the HVI light plus Conductor, for implementing the sealing end of the conductor on the supporting tube (head piece) or for connecting to other parts of the external lightning protection system (including a heat-shrinkable sleeve).
This connection element can be used for installation outside the tube for HVI light plus supporting tubes.
Art.-Nr. 819648
AE ISO RAV KF HVI 60 V2A
New
item

EB element

For discharging the electric field of the HVI light plus Conductor in the sealing end range or in other cases.
Art.-Nr. 410222
PAE 18 EX AB11 V2A
item

Air-termination mast fixing kit, D40

Fixing kit for attaching the HVI light plus Conductor to the HVI light plus supporting tubes, Ø40 mm, consisting of connection plate and fixing ring with stainless steel clamp for the sealing end (including four plastic holder halves and two cable ties).
Art.-Nr. 819642
BFS SR D40 4AE HVI LI PL AL V2A KST
item

Air-termination mast fixing kit, D50

Fixing kit for attaching the HVI light plus Conductor to the HVI supporting tubes, Ø50 mm, consisting of connection plate and fixing ring with stainless steel clamp for the sealing end (including four plastic holder halves and two cable ties).
Art.-Nr. 819283
BFS SR D50 4AE HVI LI PL AL V2A KST
item

Connection plate

Connection plate (for four conductors) for installing the HVI light plus Conductor on the supporting tube Ø40 mm (E.g. part no. 105 672, 105 673, 105 677, 105 678).
Art.-Nr. 819298
AP SR D40 4AE HVI LI PL V2A
item

Measuring point terminal

Measuring point terminal for permanent installation for connecting measuring equipment for the dielectric withstand test of HVI light plus Conductors and HVI Conductors.
Art.-Nr. 819649
MPK 18 V2A
New
item