DEHNguard® M YPV SCI (FM)
Multi-pole arrester with three-stage d.c. switching device for use in pv-systems
- Prewired modular complete unit for photovoltaic systems consisting of a base part and plug-in protection modules
- Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage due to d.c.arcs
- Tried and tested fault-resistant Y-connection prevents damage to surge protective devices in case of insulation faults in the generator circuit
- Safe replacement of protection modules without arc formation due to integrated d.c. fuse
Detailed technical information DEHNguard® M YPV SCI (FM)
|
DEHNbloc® M
Single-pole modular coordinated lighting current arrester
For protecting low-voltage consumer´s installations against surges even in case of direct lightning strokes. For use according to the lightning protection zones concept at boundaries 0A – 1.
- Coordinated spark-gap-based lightning current arrester, consisting of a base part and plug-in protection module
- Maximum system availability due to RADAX Flow follow current limitation
- No tripping of 32 A gL/gG fuses up to short-circuit currents of 50 kArms
- Discharge capacity up to 50 kA (10/350 µs)
- Directly coordinated with DEHNguard surge protective devices without additional cable length
- Low voltage protection level
- Operating state/fault indication by mark in the inspection window
- Allows for easy replacing of protection modules due to module locking system with releasing button
Detailed technical information DEHNbloc® M
|
DEHNbloc® Maxi 440 / 760
Coordinated lightning current arrester for nominal voltages 400 V and 690 V
For protecting low-voltage consumer´s installations against surges, even in case of direct lightning strokes. For use in the lightning protection zones concept at boundaries 0A – 1.
- Encapsulated non-exhausting spark gap
- High follow current extinguishing capability and follow current limitation due RADAX Flow technology
- Directly coordinated to DEHNguard surge protective devices without cable length
- Operating state/fault indication by mark in the inspection window
Detailed technical information DEHNbloc® Maxi 440 / 760 |
DEHNrail M 4P ... (FM)
4-pole pluggable surge arrester
For protecting the power supply of industrial electronic devices in switchgear cabinets against surges.
- Four-pole surge arrester consisting of a base element and plug-in protection module
- High discharge capacity due to powerful zinc-oxide- varistor/spark-gap combination
- Energy-coordinated within the Red/Line product family
- Operating state/fault indication by mark in the inspection window
- Allows for easy replacing of protection modules without tools due to module locking system with releasing button
- Nominal load current 25 A
Detailed technical information DEHNrail M 4P
|
STC-Module
Surge arrester for socket outlets with earth contact
For protecting electronic devices against surges. For use with common socket outlets with earth contact.
- Two-pole surge protection with monitoring device and disconnector
- Maximum safety due to confusion-proof Y protection circuit
- Acoustic fault indicator with optional test function
- For attaching to common socket outlets with earth contact
- Independent from the designs of the socket outlets used
- Plastic supporting ring with latch for easy attaching to already mounted socket outlets
Detailed technical information STC-Module
|
DEHNpro 230
Surge protective adapter
Adapters for protecting the power supply of electronic devices against the effects of transient overvoltages as well as high-frequency interference voltages (DEHNpro 230 F Protector).
- Surge protection with monitoring device and disconnector
- Visual operating state indication (green) and fault indication (red)
- Mains filter (for DEHNpro 230 F Protector only)
- Maximum safety due to confusion-proof Y protection circuit
Detailed technical information DEHNpro 230
|
DEHNlimit PV 1000
|
Combined lightning current and surge arrester Type 1 for use in photovoltaic systems
For protecting photovoltaic inverters against surges even in case of direct lightning strokes. For use in accordance with IEC 60364-7-712:2002-05 (Installation of photovoltaic systems).
- Prewired combined lightning current and surge arrester for use in photovoltaic generator circuits
- For use in photovoltaic installations up to 1000 V U0C STC
- High lightning current discharge capacity due to approved spark gap technology
- Maximum system availability due to spark gap technology with d.c. current extinction
Detailed technical information DEHNlimit PV 1000
|
EXFS 100 / EXFS 100 KU - for use in hazardous areas
|
Isolating spark gaps
ATEX-certified isolating spark gap for lightning equipotential bonding according to IEC 62305 with low sparkover voltage.
- For indirect connection/earthing of functionally separate parts of installations when being affected by lightning
- Device for lightning equipotential bonding according to IEC 62305 in hazardous areas
- For bridging insulating pieces, insulating flanges etc. in cathodic protected pipe sections
- For safe application in explosion protection zone 1 (gases) or 21 (dust)
- Considerably low sparkover voltage
- Considerably high a.c. current withstand capability
Detailed technical information EXFS 100 / EXFS 100 KU
|